Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
China Journal of Chinese Materia Medica ; (24): 3736-3742, 2023.
Article in Chinese | WPRIM | ID: wpr-981506

ABSTRACT

Molecularly imprinted polymers demonstrate outstanding performance in the research on trace ingredients because of their high selectivity. Stimuli-responsive molecularly imprinted polymers(STR-MIPs) with the introduction of different responsive groups on the basis of traditionally imprinted materials can undergo reversible transformations when exposed to external stimuli such as temperature, magnetism, pH or light. Such responsiveness, combined with the specific recognition, endows STR-MIPs with excellent perfor-mance in trace component studies. Traditional Chinese medicine(TCM) contains complex components with trace content, and thus STR-MIPs have broad application prospects in the enrichment analysis of trace components in TCM. This paper elaborates on the application of STR-MIPs in the enrichment analysis of trace components in TCM from the perspectives of different stimuli, summarized relevant research achievements in the recent five years to broaden the application fields of molecular imprinting, and proposed a few opi-nions about their future development.

2.
Journal of Sun Yat-sen University(Medical Sciences) ; (6): 585-591, 2019.
Article in Chinese | WPRIM | ID: wpr-817730

ABSTRACT

@#【Objective】To evaluate the efficacy of three different methods of subcostal transversus abdominis plane(TAP)block for patients undergoing open liver carcinoma resection.【Methods】A total of 60 adult patients,undergoing elective open liver carcinoma resection through a“reverse L”incision below the rib bow,were enrolled. The subjects were randomly divided into three groups(20 cases in each),including Group A,B and C,according to the position of local anesthetic injection. All patients underwent ultrasound- guided bilateral subcostal TAP block under local anesthesia. The TAP injection was injected at the middle line of the clavicle in Group A;Two separate injections were at the parasternal line and at the anterior axillary line in Group B;Multiple injections were proformed between the anterior median line and the middle axillary line in Group C. After completion of TAP block,the onset time,duration,blocking extent,hemodynamics and abdominal muscle thickness were evaluated. The operating time of TAP block and incidence of complications were recorded.【Results】The blocking extent of Group B or Group C was greater than that of Group A(P < 0.05),with no significant difference between Group B and Group C. The duration of TAP block in Group B or Group C was longer than that of Group A,while the onset time was not significantly different between the three groups. The mean arterial pressure and heart rate during laparotomy were higher than the base value in Group A,while there were no evident changes in Group B and Group C. The rectus abdominis became thinner after TAP block in all patients,but there was no significant difference in muscle thickness change among the three groups. The operating time of TAP block in the three groups was (8.4±1.9),(13.8±3.1),(23.3±4.2)min,respectively,with significant difference between any two groups(P < 0.05). None of the patients enrolled showed such complications as local anesthetic poisoning,abdominal wall hematoma,nerve injury, abdominal viscera injury,and puncture point infection.【Conclusion】The outcome of subcostal TAP block for patients undergoing open liver surgery is related to injecting position of anesthetics. Two- point-injection method is superior to one- point-injection method or multiple-point-injection method,for adequate analgesic extent as well as less operating time.

3.
Chinese Journal of Medical Instrumentation ; (6): 23-25, 2002.
Article in Chinese | WPRIM | ID: wpr-241073

ABSTRACT

Ultrasonic thrombus ablation is a newly-developed technology for percutaneous arterial recanalization. An ultrasound angioplasty device is described here in detail. The device has an adjustable power output range and distal tip longitudinal displacement range. Experimental data suggest that this ultrasound device is significantly effective in ablating fresh thrombi.


Subject(s)
Catheter Ablation , Equipment Design , Expert Systems , Thrombolytic Therapy , Transducers , Ultrasonography, Interventional , Vibration
SELECTION OF CITATIONS
SEARCH DETAIL